Overview
Autoclave Superheated Water Sterilizer is a highly efficient sterilization process for airtight containers.
The hot water circulates using sanitary mercury and passes through the heat exchanger. The heat exchanger uses industrial steam and cooling water.
Circulating mercury of this autoclave is designed with a high-efficiency circulation effect, and the temperature rises consistently during heating. The temperature of the autoclave is ideally distributed during the sterilization period. The heat exchanger conforms to the US FDA double tube plate design or adopts plate heat exchanger.
Our plant assure sterilization in conformity with good manufacturing practices for LVPs, SVP etc. and in accordance with the cGMP issued by FDA. In short, excellent engineering coupled with efficient manufacturing.
The process water is circulated through sanitary pumps via heat exchanger, industrial steam or cooling water is admitted to the external heat exchanger.
Circulation Pump is designed for high circulation performance, temperature rise averagely during heating and optimal temperature distribution during sterilization.
In order to comply with FDA standards, external heat exchanger is using double-tube sheet heat exchanger or plate heat exchanger.
Specification
● Sterilization chamber in SUS 316, SUS 316l and SUS 316Ti stainless steel.
● Piping and valves directly connected with chamber in stainless steel.
● Chamber piping all valves and fittings are sanitary class.
● Insulation by Glass wool.
● Automatic temperature controller.
● Automatic temp. Recorder - 6 points or 12 points.
● Sealed Door Packing: Use heat-resistant silicon rubber material ring packing.
● Absolute air vent filter for prevention of sterilized product contamination.
● One door or pass through type double doors.
● Single wall (cylindrical chamber) or double walls (parallelepiped chamber) body.
● All control and safety components are adapted to the higher temperature and pressure.
Standard Model
(APSR,APWR,APST,EOG) |
Capacity(Liter) |
Steam Consumption
(Kg/Hr) |
Chamber Dimension
(m/m) |
External Dimensio
(m/m) |
W |
H |
D |
W |
H |
D |
200 |
200 |
55 |
500 |
500 |
800 |
1200 |
2000 |
1100 |
360 |
360 |
60 |
600 |
600 |
1000 |
1350 |
2100 |
1300 |
480 |
480 |
100 |
600 |
800 |
1000 |
2000 |
2150 |
1300 |
600 |
600 |
120 |
600 |
1000 |
1000 |
2000 |
2150 |
1300 |
1000 |
1000 |
150 |
800 |
1000 |
1250 |
2800 |
2300 |
1550 |
1200 |
1200 |
150 |
1000 |
1000 |
1200 |
3100 |
2300 |
1500 |
1500 |
1500 |
160 |
1000 |
1000 |
1500 |
3100 |
2300 |
1500 |
1800 |
1800 |
160 |
1000 |
1200 |
1500 |
3100 |
2500 |
1800 |
2160 |
2160 |
200 |
1200 |
1200 |
1500 |
3300 |
2500 |
1800 |
5400 |
5400 |
250 |
1200 |
1500 |
3000 |
3300 |
2800 |
3300 |
※ We can accept customer specify specification.